ISO 9001 : 2015 Certified Company

A Complete
Fire Exit
Solution

India's trusted manufacturer and supplier of fire rated doors, glazed fire doors, steel doors, and complete passive fire protection systems since 2023.

0
Projects Delivered
0
Fire Rating
0
Product Lines
Adity Fire Protection - Metal Fire Door

Protecting Lives Since 2023

Pioneers in passive fire protection, delivering quality and commitment from a single window.

Message from Our Founder

"ADITY" was an idea ahead of its time when it came into being in 2023. Though the initial years were a struggle, the company has always tried to stay one step ahead by innovating and transforming its processes, refining service offerings, and redefining customer standards.

We take jobs for supply & installation of Fire Rated Glazed, Metal, Pressed Steel Doors & Window frames, Fire Hydrant Shaft Doors, Rolling Shutters, Stainless Steel Railings, and more. We also execute jobs of Fire Curtain, Fire Retardant Paint, Fire Stoppage Barrier, Fire Rated Glass & Hardware.

— Adity Jha, Managing Director

ISO 9001:2015

Certified quality management

BS 476 Tested

International testing standards

Timely Delivery

On-schedule project completion

Expert Team

Skilled professionals on every job

Adity fire doors and clean room doors
10+ Years Experience

Complete Fire Protection Range

From metal fire doors to architectural systems, we manufacture and supply the full spectrum of fire safety products.

Metal Fire Rated Door

Metal Fire Rated Door

Single leaf, equal leaf, and un-equal leaf doors with 120 minutes fire rating. Steel frame profile with galvanized steel construction.

120 min Rating 46mm Shutter BS 476
Glazed Metal Fire Rated Door

Glazed Fire Rated Door

Fire rated doors with 2-hour fire rated clear glass panels. Available in 60 and 120 minutes ratings with mineral wool insulation.

60/120 min Fire Rated Glass 1.6mm Steel
Glazed Metal Fire Rated Door with Fixed Partition

Glazed Door with Fixed Partition

Full glazed fire rated door systems with fixed partitions. Ideal for large openings requiring fire separation with visibility.

60/120 min Fixed Partition IS 3614
Steel Lead Lined Door

Steel Lead Lined Door

Nuclear and radiation protected doors for radiology and nuclear medicine applications. Built to AERB/DRS standards with 2mm lead sheet lining.

Radiation Shield AERB/DRS 2mm Lead
Fire Hose Cabinet Door

Fire Hose Cabinet Doors

Powder coated cabinet doors in PO Red with float glass vision panels. Available in single and double door configurations.

Powder Coated Vision Panel 1200x2000mm
Hollow Metal Pressed Steel Door

HMPS Doors

Hollow Metal Pressed Steel Doors with steel frame profile design. Powder coated or paint finish in desired shade.

44/46mm Pressed Steel SS 304 Hinges

India's Trusted Fire Door Manufacturer

We deliver the best without compromising on Quality, Commitment and Speed.

Skilled Professionals

Expert team with years of experience in fire safety solutions and installation.

Ethical Policies

Transparent dealings, ethical business practices, and customer-first approach.

Strong Infrastructure

Well-built manufacturing base with advanced machinery for precision production.

Reasonable Prices

Competitive pricing with easy payment modes and no compromise on quality.

Timely Delivery

On-schedule delivery with commitment to meeting project deadlines every time.

Quality Assurance

ISO 9001:2015 certified with products tested at Indian & international labs.

CAMC Services

Comprehensive annual maintenance contracts for all types of fire doors.

Pan-India Supply

Manufacturing in Noida with fire rated door supply across India.

Fire Rating Indicative Chart

As per the 2005 Revised National Building Code of India - Part 4

S.No Description and Use of Opening Wall Rating (Hrs) Door Rating (Min) — BS 476 Frame Rating (Min) — EN 1634 / IS 3614
1 Walls that separate buildings or divide a single building into designated fire areas 4 120 120
2 Enclosures of vertical communication through buildings, such as stairwells and elevator shafts 2 60 120
3 Door assemblies dividing occupancies in a building 1 60 120
4 Opening in corridors or room partitions 1 30 60
5 Opening in walls with potential severe fire exposures from exterior of building 2 60 120
6 Walls with potential moderate fire exposure from exterior of building 1 30 60

Key Regulation: Fire doors with 2 hrs. resistance shall be provided at appropriate places along the escape route and particularly at the entrance to lift lobby and stair well where a 'funnel or flue effect' may be created (Clause 4.2.9, NBC 2005).

Get In Touch

Reach out for a quote, technical consultation, or CAMC service request.

Our Offices

Visit us at any of our locations or reach out via phone or email.

Registered Office

Plot No. 50, Block-D, Ambedkar City,
Pusta Road, Sector-123, Noida 201304

Corporate Office

3rd Floor, Plot No. 68,
Near Jagannath Mandir, Sector 121,
Noida 201301

Factory

Baraut Outer Bypass, Baraka Chowk,
Baghpat 250611

Phone & Email

+91-8750413041, +91-8287429936
+91-9667930385
enquiry@aditymanagement.com

Send Us a Message